SECTION A-A SCALE 0.44 : 1 A
1 2 3 4 A B C D
C DWG NO.: CHECKED BY.: SHEET CAD FILE NO.: Print Date: DRAWN BY. MAT'L/FIN.: REV. OF TITLE.: CUSTOMER 2005 LEX PRODUCTS
.xx `0.03 (0.254) FRAC.
`
1/16 TOLERANCES UNLESS SPECIFIED: .xxxx
`
0.0025 (0.064)
11 Forest Parkway, Shelton, CT 06484
LEX PRODUCTS
.xxx `0.005 (0.127) DIMENSIONS ARE IN INCHES (mm) THE INFORMATION CONTAINED HEREIN IS PROPRIETARY TO LEX PRODUCTS ANG.
`
1/4
~
REPRODUCED OR DISCLOSED IN WHOLE OR IN PART OR USED FOR ANY DESIGN OR MANUFACTURE EXCEPT WHEN SUCH USER POSSESSES WRITTEN AUTHORIZATION FROM LEX PRODUCTS CORP. CORP AND SHALL NOT BE
OBL1B04K7XXXXG
ptillinghast Cellular South
QN051006-002.idw
8.50 10.00 8.50 0.13 1.50 7.00 0.75 3 4.13 NOTES: 1) ENCLOSURE TO BE CONSTRUCTED OF 1/8" ALUMINUM. 2) ENCLOSURE SHALL BE CONSTRUCTED TO CONFORM WITH NEMA 3R SPECIFICATIONS. 3) ALL EXTERNAL WELDS ON ENCLOSURE WILL BE GROUND SMOOTH. 4) ENCLOSURE SHALL HAVE A HINGED LOWER ACCESS DOOR THAT WILL FEATURE A HASP TO PROVIDE FOR LOCKING THE UNIT CLOSED 5) HINGE OF LOWER ACCESS DOOR WILL BE WELDED INTO PLACE. 6) EACH UNIT SHALL FEATURE FOUR (4) MALE CAM CONNECTORS. 7) CAM CONNECTORS WILL BE AFIXED TO A REMOVABLE PANEL. 8) BACK OF UNIT IS ALSO OF 1/8" ALUMINUM AND IS SUITABLE FOR DRILLING OF CONDUIT ACCESS HOLE. 9) A 4" ON CENTER HANDLE WILL BE PROVIDED TO FACILITATE DOOR OPENING AND CLOSURE. 1.00 7.00 FOUR CAM ENCLOSURE
n
0.38, 4 PL. D .6